Effectiveness of point-of-use/point-of-entry systems to remove per- and polyfluoroalkyl substances from drinking water

EPA researchers tested three commercially available reverse osmosis systems and two carbon media using water designed to represent a contaminated Colorado aquifer. Both approaches could reduce PFAS to below detection under tested conditions, with performance depending on operation and water quality.

Peer reviewed research · March 18, 2019 · Pilot

Effectiveness of point-of-use/point-of-entry systems to remove per- and polyfluoroalkyl substances from drinking water

Craig Patterson, Jonathan Burkhardt, Donald Schupp, E Radha Krishnan, Stephen Dyment, Steven Merritt, Lawrence Zintek, Danielle Kleinmaier · AWWA water science

Findings and study details

EPA researchers tested three commercially available reverse osmosis systems and two carbon media using water designed to represent a contaminated Colorado aquifer. Both approaches could reduce PFAS to below detection under tested conditions, with performance depending on operation and water quality.

Study context: The membrane tests were short-term and used historical treatment goals; the results do not certify current products or guarantee long-term household performance.