Back to Home HubBack to Remediation and Technology

PFAS cleanup research

Predicting per- and polyfluoroalkyl substances removal in pilot-scale granular activated carbon adsorbers from rapid small-scale column tests

The researchers compared rapid small column tests with pilot carbon filters in several water matrices. Their revised scale-up approach better predicted when PFAS would break through the carbon, helping utilities estimate replacement needs.

Peer reviewed research · March 19, 2024 · Pilot

Predicting per- and polyfluoroalkyl substances removal in pilot-scale granular activated carbon adsorbers from rapid small-scale column tests

Zachary R Hopkins, Detlef R U Knappe · AWWA water science

Findings and study details

The researchers compared rapid small column tests with pilot carbon filters in several water matrices. Their revised scale-up approach better predicted when PFAS would break through the carbon, helping utilities estimate replacement needs.

Study context: The protocol was validated within the tested water matrices and breakthrough range; it does not make every carbon or water source interchangeable.

Method
Adsorption and ion exchange
Material studied
Drinking water
DOI
10.1002/aws2.1369

Read the free full paper

Link to this study

Complete text access checked November 18, 2026.