Fate of biosolids-bound PFAS through pyrolysis coupled with thermal oxidation for air emissions control
Lloyd J Winchell et al. · Water Environment Research
Findings and study details
A laboratory pyrolysis unit was coupled to a thermal oxidizer so researchers could track targeted PFAS across biosolids, biochar, and exhaust. The system reduced measured PFAS by 99.4% on a molar basis; shorter-chain compounds made up most reportable PFAS in the flue gas.
Study context: The targeted analysis does not close the total fluorine balance or exclude unmeasured products of incomplete destruction.
- Method
- Heat and pressure
- Material studied
- biosolids, air emissions
- DOI
- 10.1002/wer.11149