Back to Home HubBack to Remediation and Technology

PFAS cleanup research

Validation of supercritical water oxidation to destroy perfluoroalkyl acids

Two continuous-flow validation runs tested supercritical water oxidation of a firefighting-foam concentrate while sampling liquid and gaseous outputs. Combined destruction and removal efficiency for 12 measured perfluoroalkyl acids exceeded 99.999%, while measured overall defluorination was about 62.6%.

Peer reviewed research · February 22, 2022 · Pilot

Validation of supercritical water oxidation to destroy perfluoroalkyl acids

Jeffrey T. McDonough et al. · Remediation Journal

Findings and study details

Two continuous-flow validation runs tested supercritical water oxidation of a firefighting-foam concentrate while sampling liquid and gaseous outputs. Combined destruction and removal efficiency for 12 measured perfluoroalkyl acids exceeded 99.999%, while measured overall defluorination was about 62.6%.

Study context: Fluoride was not measured in the gaseous effluent, leaving an incomplete fluorine balance; high target-compound removal is not the same as demonstrated complete mineralization.

Method
Heat and pressure
Material studied
water, AFFF concentrate, air emissions
DOI
10.1002/rem.21711

Read the free full paper

Link to this study

Complete text access checked November 18, 2026.