Reverse osmosis and nanofiltration
Explore how membranes separate PFAS, what household and treatment plant studies have found, and where the rejected chemicals go.
In this entry
- One water stream becomes two
- The membrane and the molecule both matter
- Evidence from utilities and homes
- Operation is more than installing a membrane
- A certified system has a defined claim
- Concentrate completes the treatment picture
- Sources
One water stream becomes two
Reverse osmosis, or RO, uses pressure to move water through a semipermeable membrane. The treated stream passing through is called permeate. The remaining stream contains rejected dissolved substances and is called concentrate or reject water. Nanofiltration, or NF, uses a related membrane separation approach with different selectivity.
These processes separate PFAS from some of the water. They do not ordinarily destroy the molecules. Membrane treatment requires evaluating permeate quality and concentrate volume and composition. A high removal percentage describes separation performance, not disappearance from the overall system. [1]
The membrane and the molecule both matter
The complete review of PFAS in membrane concentrates explains the distinction between separating PFAS from water and managing the concentrated stream that remains. A membrane’s performance depends on its design and the compounds and operating conditions being evaluated. Nanofiltration and reverse osmosis should not be treated as interchangeable products.
Ask which compounds were tested, how the system was operated, and what concentrations were measured in treated water. Rejection of one chemical under one set of test conditions does not guarantee identical performance for all PFAS or every installation. The concentrate requires its own handling and disposal assessment. [1] [5]
Evidence from utilities and homes
Herkert and colleagues tested residential treatment systems in North Carolina. The complete, legally available paper below reports near complete removal of the evaluated PFAS by the under sink reverse osmosis systems tested, while results for other filter types varied. The study identifies the chemicals, households, and conditions behind its findings.
Those findings are useful evidence about the evaluated systems, rather than a guarantee for an untested device today. The membrane, installation, maintenance, and water entering a home still matter. Product claims should name the compounds tested and the conditions used, and actual treated water measurements can help establish performance at a particular installation. [2]
Operation is more than installing a membrane
Household RO systems often include sediment and carbon pretreatment, the membrane itself, and additional components such as storage or a final cartridge. Pretreatment protects the membrane from particles and other conditions that can impair its performance. Feed pressure and temperature influence the amount of treated water produced.
Patterson and colleagues’ 2019 household treatment investigation examined installation, startup, and continuous or intermittent operation under specified water conditions. Those details matter because a device’s operating pattern differs from a single laboratory challenge. Follow the complete system’s instructions for flushing, cartridge changes, membrane replacement, sanitation, and checking connections. A leaking or bypassed treatment path cannot deliver the intended separation. [3]
A certified system has a defined claim
A small unit serving one drinking water faucet is point of use treatment. It does not automatically treat a refrigerator line or other faucet. A point of entry installation treats water entering the building and has different capacity and plumbing demands.
For either arrangement, confirm the exact certified model, replacement elements, and contaminant reduction claim. NSF lists specific PFAS claims for certain systems, including RO devices. Certification to an RO standard alone should not be read as proof of every optional contaminant claim. Also distinguish rejection of dissolved salts from measured PFAS performance: a general water quality indicator is not an individual PFAS test. [4]
Concentrate completes the treatment picture
Membrane concentrate contains rejected chemicals, often at higher concentrations than in the incoming water. Water recovery describes the proportion of feed water collected as permeate. Higher recovery leaves a smaller concentrate stream, but can increase its concentrations and complicate operation.
Emily Tow and colleagues reviewed PFAS concentrate management in 2021, including further separation, destructive treatment, and disposal or containment approaches. The appropriate choice depends on the stream and location. At household scale, reject water typically follows the unit’s prescribed drain connection. At utility scale, concentrate management is an essential part of design. Separation protects one water stream while leaving another environmental management task to solve. [1]