← Back to Home Hub← Back to Understanding the Evidence

Reading a PFAS laboratory report

Work through sample details, units, reporting limits, quality checks, and comparisons without mistaking a laboratory number for the whole story.

In this entry
  1. Identify what was actually sampled
  2. Understand the units before comparing numbers
  3. Detection and reliable measurement are different
  4. A nondetect is not zero
  5. Look at the quality checks
  6. Compare like with like
  7. Sources

Identify what was actually sampled

Start with the sample identification, collection date, location description, and sample type. Drinking water from a kitchen faucet is different from untreated source water, groundwater from a monitoring well, wastewater, soil, or blood. A laboratory calls the type of material its matrix. An analytical method must be suitable for that matrix.

Find the method name and the list of compounds included. A report can accurately describe every chemical on its panel while saying nothing about PFAS outside that panel. Keep the complete report, including its narrative and footnotes, rather than saving only the results table. [1]

Understand the units before comparing numbers

A concentration tells you how much chemical is in a given amount of water or another material. Drinking water information often uses parts per trillion (ppt) or parts per billion (ppb). A laboratory may write these as nanograms per liter (ng/L) or micrograms per liter (µg/L). For dilute drinking water, 1 ppt is approximately 1 ng/L, and 1 ppb is approximately 1 µg/L.

One part per billion equals 1,000 parts per trillion. To change ppb to ppt, multiply by 1,000. To change ppt to ppb, divide by 1,000. Hypothetical example: 0.006 ppb equals 6 ppt. The laboratory could also write these as 0.006 µg/L and 6 ng/L. The different numbers describe the same concentration.

EPA’s UCMR 5 Data Finder reports results in µg/L, or ppb, and gives the same conversion to ng/L, or ppt. Using the same unit helps you compare a water report with an appropriate drinking water standard. The unit itself does not say whether the result meets that standard.

A nanogram is one billionth of a gram; a microgram is one millionth of a gram. Soil may use nanograms per gram (ng/g) or micrograms per kilogram (µg/kg), which are equivalent to each other. These describe chemical mass relative to soil mass. A water value and a soil value do not describe the same material, even when both use parts per billion. [2] [6]

Detection and reliable measurement are different

A detection limit concerns the method’s ability to distinguish a signal from background. A reporting or quantitation limit concerns the concentration at which results can be reported with the required measurement performance. Laboratories and programs use different terms and reporting conventions, so read the definitions printed on the report.

A value between these limits may be reported as estimated, sometimes with a qualifier such as J. ND, U, or a less than symbol can indicate different reporting decisions. The laboratory’s qualifier key explains which limit applies. A qualifier is information about a result, not something to delete when copying it. [3]

A nondetect is not zero

Hypothetical example: a water report states PFOA less than 2 parts per trillion, also written <2 ng/L. The laboratory has not distinguished zero from a concentration below the stated reporting level. A second laboratory with a lower cutoff might report a numerical concentration for the same water.

Read the laboratory’s notes about ND, U, J, and any less than sign. Ask which cutoff applies, whether it changed after dilution, and whether a result was estimated. Comparing the percentage of samples with detections also requires knowing these cutoffs. Different reporting rules can produce different detection counts even without a change in the water itself. [3] [1]

Look at the quality checks

A method blank checks for contamination introduced during laboratory work. A field blank can help investigate contamination associated with collection or handling. Duplicate samples examine repeatability. Recovery checks examine whether the analytical process recovers known added material adequately. These controls answer different questions.

Read any narrative about contamination, sample condition, holding time, interference, or dilution. A diluted sample can have a higher reporting limit. None of these notes automatically makes a sample useless, but they may affect which comparisons are defensible. When a qualifier is unclear, ask the laboratory what it means for that specific result. [1]

Compare like with like

For comparisons over time, match the compound list, units, reporting limits, method, and sampling point. A rise in the sum can happen because more compounds were measured. A change in detection frequency can occur because the reporting limit became lower. Sludge and soil comparisons also need a consistent wet weight or dry weight basis because moisture changes the amount of solid material represented.

A blood report answers another question entirely. It measures selected PFAS in a person’s sample. ATSDR explains that the result does not identify a present or future illness or provide a treatment plan. Environmental and blood concentrations cannot be substituted for each other. [4] [5]

See the work

A researcher wearing a cap, glasses, gloves, and a protective apron works with sample collection equipment inside a field vehicle.
Field sampling at the Delaware River

Lucas Sirotniak works on PFAS surface water sampling at the Delaware River in Trenton, New Jersey. Careful collection and handling are part of producing a useful laboratory result.

Photo: Jacob Gray, U.S. Geological Survey · Public domain

Original photograph and credit (opens a new tab)

Read the sources