← Back to Home Hub← Back to Ecology & Environment

Landfills, Waste & Secondary Releases

What happens after PFAS products are discarded, including leachate, landfill gas, precursor changes and the difference between capture and destruction.

In this entry
  1. Disposal does not end the chemical’s story
  2. Leachate carries chemicals out of waste
  3. The mixture changes on the way
  4. Gas requires its own assessment
  5. Capture and destruction are different outcomes
  6. Evaluating a waste proposal
  7. Sources

Disposal does not end the chemical’s story

A discarded product can contain PFAS in coatings, smaller chemical ingredients or residues. Disposal places those materials in a new environment rather than erasing their chemistry. Moisture, oxygen availability and contact with other waste influence what can move or transform.

A full waste assessment follows the material beyond the collection bin. Liquid leaving waste and the substances remaining in solids can have different chemical patterns. The receiving facility, collection systems and final treatment all matter when evaluating where contamination might travel. [1] [3]

Leachate carries chemicals out of waste

Leachate is liquid that has contacted waste and collected dissolved or suspended substances. In the waste vehicle and landfill investigation described below, both fresh vehicle liquid and landfill leachate contained PFAS. That establishes a pathway worth measuring, without giving a release rate for every landfill.

The amount carried away depends on both concentration and liquid volume. A treatment report should identify what was sampled, the flow, the chemical list and where the liquid went next. A result for collected leachate does not establish the condition of nearby groundwater. [1] [4]

The mixture changes on the way

Waste contains both terminal PFAS and precursors that can transform. Researchers compared liquid from commercial and residential waste collection vehicles with older leachate at the receiving landfill in a study published in the January 2021 journal issue. Precursors made up much of the measured mixture in the truck liquids, while terminal acids dominated the landfill leachate. The difference was consistent with chemical transformation during disposal.

That finding matters for interpretation. Testing only the compounds common in older leachate can overlook chemicals arriving with fresh waste. The apparent disappearance of a precursor does not, by itself, demonstrate removal of its fluorinated breakdown products. [1]

Gas requires its own assessment

Landfill gas is a separate pathway from leachate. Some neutral PFAS, including fluorotelomer alcohols, can enter air more readily than the charged acids commonly measured in water. A water test is not an air test.

A meaningful gas assessment identifies the compounds targeted, how gas was collected and what happened during gas treatment. Detecting PFAS in gas does not by itself establish the amount reaching a neighboring home. Measurements at the source and an assessment of movement through air answer different parts of that question. [3] [4]

Capture and destruction are different outcomes

A treatment process may move PFAS from a large volume of water into a smaller concentrate, filter material or separated foam. That can make the water cleaner without destroying the captured chemicals. The resulting material still needs management. Landfill leachate also contains many other substances that can interfere with treatment, so results from relatively clean drinking water do not automatically predict performance on leachate.

Destruction requires evidence that the chemical structure has been broken down, including attention to reaction products and where fluorine ends up. The name of a technology, or a lower concentration in one output, is not enough to establish complete destruction. [2]

Evaluating a waste proposal

Follow each output. Which liquid is collected, which solids remain, and which air or gas streams leave? If PFAS are captured in filters or concentrates, the proposal needs to identify the destination and subsequent treatment of those residual materials. A lower concentration in one stream cannot account for all the material entering a process.

Performance evidence should match the actual waste and operating conditions. Sampling plans need clear chemical lists, appropriate reporting limits and quality checks. Where a process claims destruction, its evidence must address transformation products rather than treating disappearance of selected starting compounds as the entire answer. [2] [4]

See the work

An autonomous boat investigates a landfill and creek connection

See monitoring work at Lower Darby Creek near Philadelphia, where researchers investigate movement of PFAS and other contaminants from a former landfill through groundwater into a creek.

U.S. Geological Survey · Maryland Delaware D.C. Outreach Team

Watch at the original publisher (opens a new tab)